Additional Grounding Wire At Maf225C - Bosch Rexroth IndraDyn A Series Project Planning Manual

Asynchronous motors mad/maf
Table of Contents

Advertisement

Rexroth IndraDyn A

Additional Grounding Wire at MAF225C

DOK-MOTOR*-MAD/MAF****-PR03-EN-P
In accordance with EN 60034--1:2004 (11.1 Grounding of Machines),
motors of frame size MAF225C must additionally be grounded with a
separate grounding wire with a minimum core cross-section of 16 mm
To this end, a connecting screw (Fig. 8-2) with thread M12 has been
provided at the end shield of the MAF225C. By means of this connection
screw, fasten the additional grounding wire with a ring cable lug for thread
M12.
(1):
Connecting screw for the additional grounding wire
Fig. 8-2:
Additional grounding wire at MAF225C
Connection Techniques
Erdung_MAF225.tif
8-3