Rexroth IndraDyn A
8.4

Power Connection with Terminal Box

DOK-MOTOR*-MAD/MAF****-PR03-EN-P
IndraDyn A motors for drive combinations with high DC bus voltage are
equipped in the terminal box with a terminal strip or terminal blocks for
cables with wire end ferrules
drive
controler
(1):
Electrically conducting connection to motor housing
(2):
Shield connection via cable clamp of strain relief in the screwed
connection
(3):
Only one PTC sensor is evaluated. Connect the spare sensor only if
necessary
Fig. 8-6:
Terminal box, diagram
Note:
• The brake connections are assigned only if the motor was
manufactured with the "brake" option.
• Only one of the PTC thermistor connector pairs (3-4 or 5-6)
in the motor cable should be connected to the motor; the
other one pairs serves a spare.
• Do not remove or damage the seal glued into the cover.
• Observe the size of the screwed cable connection and
connection thread for the cable inlet into the terminal box.
• In particular, heed a sorted and de-energized laying of the
connection cables within the terminal box to avoid abrasion
or pressure marks on the cables.
• The connections of the motor-windings in the terminal box
must not be removed.
Connection Techniques
terminal block
M
terminal strip
MAx_Power_Connect2.EPS
8-5