Mounting Surface (Fastening Of The Flexplp Irplp 220 To The Floor Plate) - ABB FlexPLP IRPLP 220 Product Manual

Table of Contents

Advertisement

4.2.2 Mounting surface (fastening of the FlexPLP IRPLP 220 to the floor plate)

Inclination
If FlexPLP IRPLP 220 is mounted on a base plate, the base plate would be mounted
horizontally on the ground.
Robustness
The FlexPLP IRPLP 220 must be secured on a mounting surface that is sized to
withstand the static loads resulting from the weight of the equipment and the
dynamic loads generated by the movements of the carriages and the weight carried.
The table below lists the maximum static loads generated by a FlexPLP IRPLP 220
at nominal payload:
Load
Holes Configuration
The figures below show the countersunk and dowel holes prepared in the base
body of the horizontal axis.The unit must be secured with socket head hex screws
M8 (DIN 7984) and two 8 mm dowel pins.
The table below gives the detail numbers of holes and dimensions depending on
the strokes.
Stroke (mm)
190 mm
270 mm
350 mm
430 mm
510 mm
590 mm
670 mm
xx1800002124
Product manual - FlexPLP IRPLP 220
3HAW050041018-001 Revision: C
4.2.2 Mounting surface (fastening of the FlexPLP IRPLP 220 to the floor plate)
First horizontal axis
600 kg
Body length L0
(mm)
480 mm
560 mm
640 mm
720 mm
800 mm
880 mm
960 mm
© Copyright 2016 - 2018 ABB. All rights reserved.
4 Installation and commissioning
Second horizontal axis
500 kg
Pin holes dis-
Number of
tance L (mm)
countersunk
holes
240 mm
8
320 mm
8
320 mm
8
400 mm
8
480 mm
8
560 mm
8
640 mm
12
Vertical axis
220 kg
N x M
(No. x mm)
1x80 mm
1x80 mm
1x160 mm
1x160 mm
1x160 mm
1x160 mm
2x160 mm
Continues on next page
59

Advertisement

Table of Contents
loading

Table of Contents