7.6 SMB Battery pack replacement

General
The SMB box uses a battery for the memory backup in order to maintain position
data. The battery reference number is 3HAC16831-1.
The battery should be replaced:
Instructions
Replace the SMB battery as follows:
1
2
3
4
5
6
7
8
Product manual - FlexPLP IRPLP 220
3HAW050041018-001 Revision: C
Every three years.
When the battery is going flat. This is generally shown by an error code on
the FlexPendant screen (38213). Information about error codes can be found
in the FlexPendant documentation.
Note
In a new system the batteries are charged to full capacity after a few hours in
STANDBY mode.
Action
Position all of the carriages at the calibration point. See
Switch off the power on the SMB box.
WARNING
Turn off all electric power and pneumatic pressure supplies to the unit!
Open the SMB box and locate the battery.
Cut the plastic straps.
Unplug the 2 wires cable from the board and remove the battery pack.
Place the new battery pack, plug the connector on the board, and secure the pack
with straps.
Close the SMB box, switch on the power.
Update the revolution counters of each axis.