11.3

[Velocity window (Obj. 606Dh)]

[Velocity window (Obj. 606Dh: 00h)]

Data Type
Access
U16
RW
Description
In the profile velocity mode (pv), when the time set in [Velocity window time (Obj. 606Eh)] elapses in a state where the
difference between the command velocity and the current velocity is equal to or below the setting value of this object, bit 10 of
[Statusword (Obj. 6041h)] turns on.
The description of the object varies as shown in the table below, depending on the combination of the setting of [Pr. PT01.1
Speed/acceleration/deceleration unit selection] and the connected servo motor.
[Pr. PT01.1]
0 (encoder unit)
1 (command unit)
11.4

[Velocity window time (Obj. 606Eh)]

[Velocity window time (Obj. 606Eh: 00h)]

Data Type
Access
U16
RW
Description
Refer to the following object.
Page 91 [Velocity window (Obj. 606Dh)]
11.5

[Velocity threshold (Obj. 606Fh)]

[Velocity threshold (Obj. 606Fh: 00h)]

Data Type
Access
U16
RW
Description
In the profile velocity mode (pv), when the time set in [Velocity threshold time (Obj. 6070h)] elapses in a state where the
current velocity is equal to or below the setting value of this object, bit 12 of [Statusword (Obj. 6041h)] turns on.
The description of the object varies as shown in the table below, depending on the combination of the setting of [Pr. PT01.1
Speed/acceleration/deceleration unit selection] and the connected servo motor.
[Pr. PT01.1]
0 (encoder unit)
1 (command unit)
Mapping
Default
RXMAP
Refer to the
following.
Connected servo motor
Rotary servo motor
Linear servo motor
Mapping
Default
RXMAP
10
Mapping
Default
RXMAP
Refer to the
following.
Connected servo motor
Rotary servo motor
Linear servo motor
Range
Units
0 to 65535
vel units
Default
Units
2000
0.01 r/min
0.01 mm/s
20000
pulse/s
Range
Units
0 to 65535
ms
Range
Units
0 to 65535
vel units
Default
Units
5000
0.01 r/min
0.01 mm/s
20
pulse/s
11 Profile Velocity Mode Objects
11.3 [Velocity window (Obj. 606Dh)]
Save
Parameter
Possible
Refer to the
following.
Parameter
[Pr. PC72]
[Pr. PV19]
Save
Parameter
Possible
[Pr. PC73]
Save
Parameter
Possible
Refer to the
following.
Parameter
[Pr. PC65]
[Pr. PV20]
11
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-gMelservo mr-j5w-gMelservo-jet mr-jet g seriesMelservo-j5 seriesMelservo mr-j5-g seriesMelservo mr-j5w-g series

Table of Contents