Mitsubishi Electric Melservo J5 Series User Manual page 61

Hide thumbs Also See for Melservo J5 Series:
Table of Contents

Advertisement

8.28
[Phase current (Obj. 2C37h)]
[Phase current (Obj. 2C37h: 00h)]
Data Type
Access
U8
RO
Description
The total number of Sub Indexes (= 3) is returned.
[U phase current (Obj. 2C37h: 01h)]
Data Type
Access
I16
RO
Description
The U-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
[V phase current (Obj. 2C37h: 02h)]
Data Type
Access
I16
RO
Description
The V-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
[W phase current (Obj. 2C37h: 03h)]
Data Type
Access
I16
RO
Description
The W-phase current value is displayed in increments of 0.1 % in relation to the rated current as 100 %.
Mapping
Default
Impossible
Mapping
Default
TXMAP
Mapping
Default
TXMAP
Mapping
Default
TXMAP
Range
Units
3 (fixed)
Range
Units
-32768 to 32767
0.1 %
Range
Units
-32768 to 32767
0.1 %
Range
Units
-32768 to 32767
0.1 %
8 Manufacturer Specific Control Object
8.28 [Phase current (Obj. 2C37h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
8
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-gMelservo mr-j5w-gMelservo-jet mr-jet g seriesMelservo-j5 seriesMelservo mr-j5-g seriesMelservo mr-j5w-g series

Table of Contents