Huawei NetCol5000-C030H90D0 User Manual page 22

In-row chilled water smart cooling product
Table of Contents

Advertisement

NetCol5000-C(030, 032, 065) In-row Chilled Water
Smart Cooling Product
User Manual (2019)
High Compatibility
Intelligent Monitoring
Quick Installation and Commissioning
Easy Maintenance
Issue 03 (2020-08-30)
Intelligent differential pressure control (optional): Solves the issue of hot
spots due to insufficient air volume to improve reliability.
Temperature and humidity sensor: A maximum of ten remote ambient
temperature and humidity sensors can be configured to monitor the
temperature and humidity of data centers, improving reliability.
Power supply: The NetCol5000-C can run in the working condition where the
input system is 220 V to 240 V, single-phase, and 50 Hz or 60 Hz. They can
protect against overload and short circuits.
Control mode: The NetCol5000-C supports multiple control modes, including
air supply control, cold aisle control, return air control, hot aisle control, and
pressure differential control. You can select control modes based on the
characteristics of your data centers.
Users can monitor and configure the smart cooling product on a client.
The 7-inch thin film transistor (TFT) display panel with the true-color
touchscreen displays the equipment running mode and status and allows
users to set equipment parameters.
After the equipment is leveled and secured onsite, users need only to connect
pipes and cables before starting the equipment.
Startup wizard: A startup wizard is provided to guide operators through the
commissioning process. The smart cooling product running data is collected
automatically, which helps O&M personnel evaluate the status of the key
components of the smart cooling product, and simplifies O&M.
Real-time display: The cooling capacity, air volume, power, and fan speed can
be displayed in real time on the control panel, which helps O&M personnel
grasp the running status of smart cooling products.
Professional diagnosis system: Common alarms and faults can be located
intelligently. The intelligent and highly efficient system lowers skill
requirements, simplify O&M, and reduce O&M time.
Startup wizard: A startup wizard is provided to guide operators through the
commissioning process. The smart cooling product running data is collected
automatically, which helps O&M personnel evaluate the status of the key
components of the smart cooling product, shortens the startup
commissioning duration, simplifies the startup commissioning, and reduces
the commissioning costs.
Automatic fault diagnosis: Automatically identifies the root cause when a
fault occurs and intelligently excludes irrelevant fault causes. This function
helps O&M personnel perform quick maintenance, greatly simplifying O&M
and reducing the troubleshooting time.
Health management: Forecasts the life of key components and prompts for
component replacement. The function allows operators to know the life span
Copyright © Huawei Technologies Co., Ltd.