2.6.4
Parameters related to CC-Link IE Field Network
Basic
The following parameters are used for CC-Link IE Field Network Basic communication. Set the parameters as required.
Pr.
Name
541
Frequency command sign
N100
selection
544
CC-Link extended setting
*1
N103
1426
Link speed and duplex
*1
mode selection
N641
1442
Ethernet IP filter address 1 0
*1
N660
1443
Ethernet IP filter address 2 0
*1
N661
1444
Ethernet IP filter address 3 0
*1
N662
1445
Ethernet IP filter address 4 0
*1
N663
1446
Ethernet IP filter address 2
*1
range specification
N664
1447
Ethernet IP filter address 3
*1
range specification
N665
1448
Ethernet IP filter address 4
*1
range specification
N666
804
Torque command source
D400
selection
810
Torque limit input method
H700
selection
*1
The setting is applied after an inverter reset or next power-ON.
 CC-Link extended setting (Pr.544)
• Use this parameter to select the function of the remote registers for the CC-Link IE Field Network Basic.
Pr.544 setting
0 (initial value)
Compatible with CC-Link Ver.1
1
Compatible with CC-Link Ver.1
12
Compatible with the double setting of CC-Link Ver.2
14
Compatible with the quadruple setting of CC-Link Ver.2
18
Compatible with the octuple setting of CC-Link Ver.2
100
Compatible with CC-Link Ver.1
112
Compatible with the double setting of CC-Link Ver.2
114
Compatible with the quadruple setting of CC-Link Ver.2
118
Compatible with the octuple setting of CC-Link Ver.2
*1
Refer to the PLC Function Programming Manual.
 Frequency command with sign (Pr.541)
• The start command (forward/reverse rotation) can be inverted by adding a plus or minus sign to the value of the frequency
command sent through the CC-Link IE Field Network Basic.
Initial
Setting range
value
0
Signed frequency command value
0
1
Unsigned frequency command value
0, 1, 12, 14, 18,
The function of the remote registers can be extended when the CC-
0
100, 112, 114,
Link IE Field Network Basic is used.
118
0
0 to 4
Set the communication mode (full-duplex/half-duplex).
0 to 255
Set the range of connectable IP addresses for the network devices.
(When Pr.1442 to Pr.1445 = "0 (initial value)", the function is
invalid.)
9999
9999
0 to 255, 9999
9999
In the torque control mode, the torque command source can be
0
0, 1, 3 to 6
selected.
0
0 to 2
The torque limit input method can be selected.
Description
Description
Refer to page
40
41
41
42
42
*1
PLC function
2. Ethernet Communication
2.6 CC-Link IE Field Network Basic
1
2
3
4
5
6
7
8
9
10
39