Cc-Link Parameters; Cc-Link Extended Setting (Pr. 544) - Mitsubishi Electric 700 Series Programming Manual

700 series plc function programming manual
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2.2 CC-Link Parameters

2.2.1

CC-Link Extended Setting (Pr. 544)

Remote register function can be extended.
Parameter
Name
Number
CC-Link extended
544
setting
*1
The program used for conventional series inverter (FR-A5NC) can be used.
*2
When using double, quadruple and octuple settings of the CC-Link Ver.2, station data of
the master station must be set to double, quadruple and octuple also.
(If the master station is CC-Link Ver.1 compatible station, the above setting can not be
made.)
REMARKS
The setting change is reflected after an inverter reset.
Initial
Setting
CC-Link
Value
Range
0
1
12
*2
14
*2
18
*2
0
100
112
*2
114
*2
118
*2

CC-Link Parameters

Description
Ver.
Occupies one station
(FR-A5NC compatible)
1
Occupies one station
Occupies one station double
Occupies one station
2
quadrople
Occupies one station octuple
Occupies one station
1
(PLC function)
Occupies one station double
(PLC function)
Occupies one station
2
quadrople (PLC function)
Occupies one station octuple
(PLC function)
*1
2
49