Mitsubishi Electric 800 Series Instruction Manual page 94

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Register
Definition
W8011
Capacity (1st and 2nd characters) Read
W8012
Capacity (3rd and 4th characters)
W8013
Capacity (5th and 6th characters)
• Serial number
Register
W8101
Serial number (1st and 2nd characters)
W8102
Serial number (3rd and 4th characters)
W8103
Serial number (5th and 6th characters)
W8104
Serial number (7th and 8th characters)
W8105
Serial number (9th and 10th characters)
W8106
Serial number (11th and 12th characters)
W8107
Serial number (13th and 14th characters)
W8108
Serial number (15th and 16th characters)
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
 Data specified in the command
• Device code
A one byte numerical value is sent.
• Device No. (first device No.) specification
The device No. is specified for reading/writing data.
When consecutive devices are specified, the first device No. is specified. The device No. is specified in decimal or
hexadecimal depending on the device type.
A three byte numerical value is sent from the lower byte to the upper byte. If the device No. is a decimal value, convert it
to a hexadecimal value.
(Example) Device No. of Internal relay M63 / Input X20
M63
X20
H3F H00
H00
H20 H00 H00
Internal relay M63 has a decimal device No. Convert the decimal value to a hexadecimal value H00003F. The value is sent
in the order 3F, 00, and 00. The device No. of Input X20 is regarded as H000020 and sent in the order 20, 00, and 00.
• Specification of the number of devices
The number of devices is specified for reading/writing data.
A two byte numerical value is sent from the lower byte to the upper byte.
(Example) Number of devices: 5 / 20
5 devices
20 devices
H05 H00
H14 H00
• Specification of the number of devices for bit access
The number of devices is specified for reading/writing data in bit units. The number is used in the Write Random command
(refer to page
page
96).
(Example) Number of devices: 5 / 20
5 devices 20 devices
H05
H14
Read/write
Read
Read
Definition
Read/write
Read
Read
Read
Read
Read
Read
Read
Read
Remarks
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01 kW
increments.
"H20" (blank code) is set for blank area.
Example) 0.75K: "
7" (H20, H20, H20, H20, H20, H37)
The serial number can be read in ASCII code.
Remarks
2. Ethernet Communication
2.10 SLMP
1
2
3
4
5
6
7
8
9
10
93