Mitsubishi Electric 800 Series Instruction Manual page 24

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Description
*4
Address
Upper 8 bits
RWwn+D
RWwn+E
H00 (Free)
RWwn+F
Link parameter
RWwn+10
extended setting
RWwn+11
Data to be written
Link parameter
RWwn+12
extended setting
RWwn+13
Data to be written
Link parameter
RWwn+14
extended setting
RWwn+15
Data to be written
Link parameter
RWwn+16
extended setting
RWwn+17
Data to be written
Link parameter
RWwn+18
extended setting
RWwn+19
Data to be written
RWwn+1A
RWwn+1B
RWwn+1C
H00 (Free)
RWwn+1D
RWwn+1E
RWwn+1F
*1
When Pr.128 = "50, 51, 60, or 61", the register is valid. When Pr.128 = "1000 to 2011", the register is valid depending on the setting in Pr.609 or
Pr.610.
*2
The display can be changed to rotations per minute (machine speed) using Pr.37 and Pr.53.
*3
When the output frequency or the set frequency is selected as the monitor item, rotations per minute (machine speed) can be displayed using
Pr.37 and setting "4" in Pr.53.
*4
"n" indicates a value determined by the station number.
 Details of the I/O signals
The device numbers described in this section are for the station number 1. For the station number 2 and later, the device
numbers are different. (Refer to the manual for the CC-Link master module for the correspondence between device numbers
and station numbers.)
 Output signals (from the master module to the inverter)
Output signals from the master module are as follows. (Input signals to the inverter)
Device No.
RY0
Forward rotation command
RY1
Reverse rotation command
High-speed operation command (terminal
RY2
RH function)
Middle-speed operation command
RY3
(terminal RM function)
Low-speed operation command (terminal
RY4
*1
RL function)
RY5
JOG operation command 2
RY6
Second function selection
RY7
Current input selection
RY8
— (terminal NET X1 function)
RY9
Output stop (terminal MRS function)
RYA
— (terminal NET X2 function)
Refer to
page
Lower 8 bits
Instruction code
26
26
Instruction code
26
26
Instruction code
26
26
Instruction code
26
26
Instruction code
26
26
Signal
0: Stop
command
*2
1: Forward
rotation start
0: Stop
command
*2
1: Reverse
rotation start
*1
Functions assigned to terminals RH, RM, and RL are activated.
*1
*2
JOG2 signal
*2
RT signal
*2
AU signal
*3
The function assigned to Pr.185 is activated.
*1
The function assigned to terminal MRS is activated.
*3
The function assigned to Pr.186 is activated.
Description
*4
Address
Upper 8 bits
RWrn+D
RWrn+E
H00 (Free)
RWrn+F
RWrn+10
Reply code
RWrn+11
Data to be read
RWrn+12
Reply code
RWrn+13
Data to be read
RWrn+14
Reply code
RWrn+15
Data to be read
RWrn+16
Reply code
RWrn+17
Data to be read
RWrn+18
Reply code
RWrn+19
Data to be read
RWrn+1A
RWrn+1B
RWrn+1C
H00 (Free)
RWrn+1D
RWrn+1E
RWrn+1F
Description
When "1" is set, a start command is input to the inverter.
When "1" is set in RY0 and RY1, a stop command is input.
Refer to
page
Lower 8 bits
26
26
26
26
26
26
26
26
26
26
23
2. Ethernet Communication
2.5 CC-Link IE TSN