ABB PST Series Installation And Commissioning Manual page 60

Table of Contents

Advertisement

&KDSWHU 
+XPDQ0DFKLQH ,QWHUIDFH +0,
Top level
Settings
Local Control
Event Log
Status Information
Reset Events
)LJXUH  (YHQW /RJ PHQX
Top level
Settings
Local Control
Event Log
Status Information
Reset Events
)LJXUH  6WDWXV LQIRUPDWLRQ PHQX
Top level
Settings
Local Control
Event Log
Status Information
Reset Events
)LJXUH  5HVHW (YHQWV PHQX
60
 (YHQW /RJ PHQX
The Event Log menu is used to check the event log in the
softstarter. When entering this menu the twenty latest
events in the log are presented, in chronological order with
the latest event as No. 1, the second latest as No. 2 etc.
The events are presented with "type of event", date and
time.
Use navigation keys to view all entries in the event log.
 6WDWXV ,QIRUPDWLRQ PHQX
The Status information menu is used to present various
information.
The information is presented one by one on the top row.
Use navigation keys to present all information.
'LVSOD\ WH[W
Connection
Frequency
Phase L1
Phase L2
Phase L3
Run Time
No. Of Starts
SW Ver. CU
SW Ver. FU
LV Board No
MAC Address
Phase seq.
 5HVHW (YHQWV PHQX
The Reset Events menu is entered automatically when a
fault has occurred or a protection is activated. It can also
be entered via the main menu.
Use navigation keys to view if there are several events to
reset.
)XQFWLRQ
Type of connection, In Line/
Inside Delta.
Measured frequency.
Phase current L1.
Phase current L2.
Phase current L3.
Total run time of the motor.
Counted number of starts.
Software version CU.
Software version FU.
Serial No of the LV PCB.
Internal addressing.
Phase sequence indication.
1SFC132003M0201