ABB PST Series Installation And Commissioning Manual page 110

Table of Contents

Advertisement

&KDSWHU 
)LHOGEXV FRPPXQLFDWLRQ RSWLRQ
110
1R 7\SH
3DUDPHWHU
34 Read/Write
PTC Op
35 Read/Write
Ext ByPass
36 Read/Write
BP Fault Op
37 Read/Write
Warn I=High
38 Read/Write
Wa I=H Lev
39 Read/Write
Warn I=Low
40 Read/Write
Wa I=L Lev
41 Read/Write
Warn OL
42 Read/Write
Wa OL Lev
43 Read/Write
Warn SCR OL
44 Read/Write
Ph Loss Op
45 Read/Write
FB Fault Op
46 Read/Write
Freq F Op.
47 Read/Write
HS Temp Op
48 Read/Write
SCR SC Op
49 Read
In0
50 Read
In1
51 Read/Write
Relay K4
52 Read/Write
Relay K5
53 Read/Write
Relay K6
54 Read/Write
SW Outp V7
55 Read/Write
Event K4
56 Read/Write
Event K5
57 Read/Write
Event K6
58 Read/Write
Event V7
59 Read
Fieldb Ctrl
60 Read
Fieldb Type
61 Read
Fieldb Addr
'HVFULSWLRQ
Type of operation for PTC protection Stop–M, Stop–A, Ind
External By-pass contactor is used
Type of operation for by-pass moni-
tor protection
High current warning
Trip level for high current warning
Low current warning
Trip level for low current warning
Overload warning
Trip level for overload warning
Thyristor overload warning
Type of operation for phase loss
fault
Type of operation for fieldbus fault
Type of operation for frequency fault Stop–M, Stop–A
Type of operation for heat sink over
temperature fault
Type of operation for thyristor short
circuit fault
Function of programmable input In0 None, Reset, Enable,
Function of programmable input In1 None, Reset, Enable,
Function of programmable relay out-
put K4
Function of programmable relay out-
put K5
Function of programmable relay out-
put K6
Function of programmable software
output V7
Different events to include for signal-
ling with K4 if "Event" is selected
Different events to include for signal-
ling with K5 if "Event" is selected
Different events to include for signal-
ling with K6 if "Event" is selected
Different events to include for signal-
ling with V7 if "Event" is selected
Control of the softstarter with field-
bus
Type of fieldbus
Fieldbus address
5DQJH
8QLW
No, Yes
Stop–M, Stop–A
No, Yes
0,5 – 5,0
x Ie
No, Yes
0,4 – 1,0
x Ie
No, Yes
40 – 99
%
No, Yes
Stop–M, Stop–A
Stop–M, Stop–A
Stop–M, Stop–A
Stop–M, Stop–A
Jog, DOL-on, Start2
Jog, DOL-on, Start3
Run, TOR, Event
Run, TOR, Event
Run, TOR, Event
Run, TOR, Event
0 – 65535, Bit mask
see separate
description.
0 – 65535, Bit mask
see separate
description.
0 – 65535, Bit mask
see separate
description.
0 – 65535, Bit mask
see separate
description.
No, Yes
AS-I, Other
0 – 1000
1SFC132003M0201