CX320 Switch Module
User Guide
Procedure
Step 1 log in to the converged switching plane CLI.
Step 2 Run the following command on the CLI of the converged switching plane to check the current
version of the converged switching plane:
<HUAWEI> display version
The command output is as follows:
Huawei Versatile Routing Platform Software
VRP (R) software, Version 8.120 (OSCA V100R005C60)
Copyright (C) 2012-2016 Huawei Technologies Co., Ltd.
HUAWEI OSCA uptime is 0 day, 3 hours, 32 minutes
CX320(Master) 1 : uptime is
Memory
Flash
CX320 version information
1. PCB
2. MAB
3. Board
4. CPLD1
5. BIOS
6. Software Version : 5.70
Software Version indicates the current software version.
Step 3 Check whether the software version is consistent with the desired one.
l
l
Step 4 Query the alarms of the converged switching plane.
<HUAWEI> display alarm active
The command output is as follows:
1:Critical
------------------------------------------------------------------
Sequence AlarmId
------------------------------------------------------------------
The parameters are described as follows:
l
l
l
l
l
l
l
l
l
Step 5 Check whether an alarm is generated.
Issue 09 (2019-08-02)
StartupTime 2016/07/24 11:30:44
Size
: 2048 M bytes
Size
: 1024 M bytes
Version : CX320 VER A
Version : 0
Type
: CX320
Version : 6.07
Version : 2.49
If yes, go to
Step
4.
If no, contact Huawei technical support.
2:Major
3: Minor
Severity Date Time
Critical: critical alarm
Major: major alarm
Minor: minor alarm
Warning: warning alarm
Sequence: alarm sequence
AlarmId: alarm ID
Severity: alarm severity
Date Time: date and time at which an alarm is generated
Description: alarm description
If no information is displayed, no alarm is generated.
Copyright © Huawei Technologies Co., Ltd.
0 day, 3 hours, 31 minutes
4:Warning
Description
4 Configuring the CX320