Technical Specifications - Huawei CX320 User Manual

Switch module
Table of Contents

Advertisement

CX320 Switch Module
User Guide

2.9 Technical Specifications

This topic describes the physical, environmental, power, and network switching specifications
of the CX320.
Table 2-8 Technical specifications
Category
Physical
specifications
Environmental
specifications
Issue 09 (2019-08-02)
Item
Dimensions (H
x W x D)
Color
Weight
Temperature
Relative
humidity (RH,
non-
condensing)
Altitude
Corrosive air
pollutant
Particulate
pollutant
Copyright © Huawei Technologies Co., Ltd.
Specifications
388.55 mm x 35.06 mm x 272.15 mm (15.30 in. x
1.38 in. x 10.71 in.)
Silver
2.9 kg
l Operating temperature: 5°C to 40°C (41°F to
104°F) (ASHRAE Class A3 compliant)
l Storage temperature: -40°C to +65°C (-40°F to
+149°F)
l Long-term storage temperature: 21°C to 27°C
(69.8°F to 80.6°F)
l Temperature change rate < 20°C/h (36°F/h)
l Operating humidity: 5% to 85%
l Storage humidity: 5% to 95%
l Long-term storage humidity: 30% to 69%
l Humidity change rate < 20%/h
At an altitude of 900 m (2952.72 ft), the highest
operating temperature is 40°C (104°F).
When the device is used at an altitude of 900 m to
5000 m, the highest operating temperature decreases
by 1°C (1.8°F) for every increase of 300 m (984.24
ft).
l Corrosion rate of the copper test piece < 300 Å/
month (in compliance with the ANSI/
ISA-71.04-2013 gaseous corrosion level G1)
l Corrosion rate of the silver test piece < 200 Å/
month
l The ISO14664-1 Class 8 requirements are met.
It is recommended that a professional company
monitor particulate pollutants in the equipment
room.
l There is no explosive, conductive, magnetic, or
corrosive dust in the equipment room.
2 Product Overview