Measuring Input TO - Part III
5.3 Configuring the Measuring Input technology object
5. Now calculate the HW address by adding the base input address (first value of the input
6. You will find the bit number in the following table. The inputs are set in parameters 680.0
Table 5-8
Bit numbers for D410, D4x5, D4x5-2 (X122/X132), CX32, CX32-2 CU310, CU320, CU320-2
Input D4x5, CU320
Input D4x5-2,
CU320-2
-
X122.9 (DI/DO 8)
X122.8 (DI/DO 9)
X122.10 (DI/DO 9)
X122.10 (DI/DO 10)
X122.12 (DI/DO 10)
X122.11 (DI/DO 11)
X122.13 (DI/DO 11)
-
X132.9 (DI/DO 12)
X132.8 (DI/DO 13)
X132.10 (DI/DO 13)
X132.10 (DI/DO 14)
X132.12 (DI/DO 14)
X132.11 (DI/DO 15)
X132.13 (DI/DO 15)
5.3.7.4

Global measuring on D4x5-2 (X142)

Unlike (X122/X132), measuring inputs on measuring input D4x5-2 (X142) are configured in HW Config
Configuration of terminals and function as well as the fixed telegram's start address are
configured in HW Config.
To configure a measuring input on an input of D4x5-2 (X142)
The dialog box for configuring the X142 can be opened via the input/output X142 in the project
navigator. Alternatively, you can access the dialog to be configured via the HW Config by
clicking Open HW Configuration ... in the device's context menu.
Slot X142 is shown in the detail view and in the station window of the respective D4x5-2 device.
You can access the Properties dialog via the Object properties... context menu or by double-
clicking on the X142 line.
170
data) of the control unit to the offset (e.g. 256 + 3 = 301). The offset always has the value
3.
to 680.7 of the control unit, e.g. bit 1 in parameter 680.0.
Input D410, CU310,
CX32
-
X121.8 (DI/DO 9)
X121.10 (DI/DO 10)
X121.11 DI/DO 11)
-
-
-
-
Input D410-2,
Input CX32-2
CU310-2
X121.7 (DI/DO 8)
X122.9 (DI/DO 8)
X121.8 (DI/DO 9)
X122.10 (DI/DO 9)
X121.10 (DI/DO 10)
X122.12 (DI/DO 10)
X121.11 (DI/DO 11)
X122.13 (DI/DO 11)
X131.1 (DI/DO 12)
-
X131.2 (DI/DO 13)
-
X131.4 (DI/DO 14)
-
X131.5 (DI/DO 15)
-
Output Cams and Measuring Inputs
Bit
No.
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Function Manual, 04/2014