Output Cam TO - Part I
3.3 Configuring the Output Cam technology object
To parameterize an output cam:
1. In the project navigator under the folder OUTPUT CAMS, find the output cam TO that you
2. Double-click Configuration or Default in the project navigator. The window appears on the
3. Change the configuration data and output cam defaults.
4. Click Close to accept the changes.
5. Repeat steps 2 to 4 for all objects in which you want to change the configuration data and
See also
Output cam configuration (Page 38)
Defining output cam defaults (Page 43)
3.3.3

Using the expert list for output cams

For standard SIMOTION applications, necessary parameters (configuration data and system
variables) are parameterized into the Output Cam technology object directly in screen forms
or are defined automatically.
It may be necessary to change automatically defined parameters for special SIMOTION
applications. These configuration data and system variables can only be displayed and
changed in the expert list.
Note
You will find more information on working with the expert list in the
Functions functional description .
3.3.4
Output cam configuration
In the Configuration window, define the configuration data values for the output cam.
Double-clicking in the project navigator below the output cam on the Configuration element
displays the window in the working area.
38
want to parameterize. Double-click the output cam TO to display the associated objects.
workspace.
– Configuration:
Define the configuration data of the output cam here. This includes, for example, output
cam type.
– Default:
Define the output cam defaults of the system variables here. This includes, for example,
the effective direction.
output cam defaults.