Cam Track TO - Part II
4.3 Configuring the TO Cam Track
8. Assignment of an output to an output cam/cam track is supported as of V4.2 using symbolic
9. Click OK to close the window and select Project > Save from the menu.
4.3.9

Configuring cam tracks on a TM15/TM17 High Feature

1. In the project navigator, below the input/output component (TM15/TM17) that you want to
2. For the selected I/O channel, select Output cam as the function.
3. Insert a new output cam or a new cam track or use an existing one.
4. Parameterize the TO Output Cam / Cam Track
5. Double-click Configuration below the output cam or the cam track in the project navigator.
6. For high-speed, hardware-supported output cams, you can achieve an output accuracy
7. Assignment of an output to an output cam/cam track is supported as of V4.2 either by
8. Click OK to close the window and select Project > Save from the menu.
114
assignment or by entering the HW address.
use, double-click the entry Inputs/outputs. The Bidirectional Digital Inputs/Outputs window
is displayed.
Note
If you do not use symbolic assignment (see Chapter Symbolic Assignment (as of V4.2) in
the SIMOTION Runtime Basic Functions manual), you must note the offset (e.g. 3.1).
The Configuration window appears in the working area.
exceeding the servo cycle clock based on the hardware used.
If you would like to configure a high-speed output cam, select the Activate output check
box and select the Cam output (CAM) radio button.
symbolic assignment (see Chapter Symbolic Assignment (as of V4.2) in the SIMOTION
Runtime Basic Functions manual) or by entering the hardware address.