Example Of Position Measuring; Addressing The Wf 705 As - Siemens WF 705 Description

Position measuring module
Table of Contents

Advertisement

11.96
4.3

Example of Position Measuring

The standard diskette of the function blocks (FC's) contains an example of position measuring
for the use of the WF 705 in the SIMATIC S7-400.
4.4
Addressing the WF 705 as SIMATIC S7-400 Periphery
The WF 705 module can be used in the SIMATIC S7-400 in different ways:
In a SIMATIC S7-400 central unit by means of SIMATIC S5 adapter casing
In a SIMATIC S5 extension unit linked with the central unit of the SIMATIC S7-400 via
interfaces IM463-2 (S7) and IM314 (S5).
In the SIMATIC S7-400 central unit, you can plug:
Up to 8 adapter casings, i.e. up to 8 WF modules
Up to 4 IM463-2; each IM463-2 can be linked with up to 8 SIMATIC S5 extension units.
In a SIMATIC S7-400 system, you can address:
Up to 64 WF 705 modules
STEP7-Tool HWKonfig (hardware configuration) is needed for:
Configuration of the adapter casing
Configuration of the IM463-2 interface
©
Siemens AG 1990 All Rights Reserved
WF 705 (Description)
6ZB5 440-0AA02
Operation with SIMATIC S7-400
4 - 13