Cam Track TO - Part II
4.2 TO Cam Track basics
Note
Further information and the output accuracy for high-speed output cams is described in the
PM21 Catalog and in the respective product brief or commissioning/equipment manuals.
Commissioning Manual
Operating Instructions
Commissioning Manual
Commissioning Manual
Commissioning and Hardware Installation Manual
Commissioning and Hardware Installation Manual
4.2.3

Cam track parameters

4.2.3.1
Track length
The camTrackLength system variable is used to parameterize the track length. The track length
is calculated from the start of the cam track (always 0) to the end of the cam track. Usually,
the output cams of the cam track are located within the track length. The track length must not
be 0. When track length = 0, an error is reported when the cam track of a non-modulo axis is
activated. If track length = 0 for a modulo axis during cam track activation, the cam track length
is set to the axis modulo length.
4.2.3.2
Effective direction and behavior
The following diagram shows output cam behavior on switching on and off, without hysteresis,
activation or deactivation time.
Figure 4-9
The switching characteristic depends only on the position (position setpoint or actual position).
The cams on a cam track switch independently of the direction of motion, i.e. they always have
76
Terminal Modules TM15/TM17 High Feature
SIMOTION C2xx
SIMOTION D410
SIMOTION D410-2
Output cam behavior on switching on/off
SIMOTION D4x5
SIMOTION D4x5-2
Output Cams and Measuring Inputs
Function Manual, 04/2014