Cam Track TO - Part II
4.4 Programming/References of TO Cam Track
Table 4-15
Possible alarm responses
Alarm Response
NONE
DECODE_STOP
CAMTRACK_DISAB LE
4.4.4

TO Cam Track menus

4.4.4.1
Cam track menu
Grayed-out menu functions cannot be selected. The menu is only active if a Cam Track TO
window is active in the working area.
You can select the following functions:
Table 4-16
Cam track TO menu
Function
Significance/Note
Close
Select Close to close the configuration window for the cam track that is open in the working area.
Properties
Select Properties to display the properties of the cam track highlighted in the project navigator.
Configuration
Select Configuration to determine the configuration data (e.g. output cam type) of the cam track.
Default
Select Default to define the defaults of the system variables (e.g. track data and output cam data)
of the cam track.
Expert
Expert list
Select Expert list to open the expert list for the highlighted cam track. The configuration data and
system variables can be displayed and changed in this list.
Configure units
Select Configure units to open the Configure units of the object window in the working area. You can
configure the units used for the selected object here.
4.4.4.2
Cam track context menu
Grayed-out functions in the context menu cannot be selected.
126
Description
No response
Command processing is aborted, the cam track
function remains active. Execution on the technology
object can continue after _resetOutputCam or
_resetOutputCamError.
Command processing is aborted, current cam track
function is aborted. Execution on the technology
object can continue after _resetCamTrack or
_resetCamTrackError.
Application
-
The Cam Track TO can only be
reactivated after the error has been
acknowledged.
The Cam Track TO can only be
reactivated after the error has been
acknowledged.
Output Cams and Measuring Inputs