6 DEDICATED INSTRUCTIONS

6.9 JP/GP.SEND

Set
Internal device
data
Bit
Word
(S1)
(S2)
(D)
[Instruction
[Executing
symbol]
condition]
JP.SEND
GP.SEND
Setting data
Set data
Network number of the local station (1 to 239, 254)
Jn
254: The network designated by the valid module during other station
Start I/O signal of the local station's Ethernet module.
Un
(00 to FE
(S1)
Head device of the local station that stores the control data.
(S2)
Head device of the local station that stores the send data.
Local station device that is turned on for one scan by the completion of
(D)
the instruction.
(D) + 1 is turned on if the instruction execution completes abnormally.
6 - 37
This instruction sends data to another station's Q/L/QnACPU.
Link direct device
File register
Bit
Command
Command
Description
access.
: The higher 2 digits of the 3-digit I/O signal.)
H
The local devices and the file register for each program cannot be used as devices
used in setting data.
POINT
The SEND instruction can be executed only when the target station is a
Q/L/QnACPU.
(The SEND instruction cannot be executed for an ACPU connected to an
MELSECNET/10 or Ethernet network system.)
REMARKS
1) Setting values stored in Completion status ((S1) + 1) and Clock data ((S1) + 10 to
(S1) + 14) are stored into control data upon completion of the instruction.
2) The number of steps for the SEND instruction is 8.
Applicable device
Intelligent
J \
function module
device U \G
Word
JP.SEND
GP.SEND
MELSEC-Q/L
Index register
Constant
Zn
K, H
Jn
(S1)
(S2)
(D)
Un
(S1)
(S2)
(D)
1
Set by (
)
User
Character string
User, system
User
System
Others
Data type
Binary 16 bits
Device name
Bit
6 - 37