Mitsubishi Electric Melsec Q Series User Manual page 162

Ethernet interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

5 WHEN USING FILE TRANSFER FUNCTIONS (FTP SERVER)
5 - 29
change (Ethernet module dedicated command)
[Function]
[Designation format]
[Designation format]
[Designation example 1]
[Designation example 2]
[Caution]
POINT
The file attributes designated using the quote change command are explained.
(1) When changing the attribute of the file for file transfer, designate the attribute
after the change.
(2) The attributes are for changing the file to read-only or read/write enabled file.
(3) The attribute can be changed to the following for the files stored in the CPU
module memory using this command:
"r" (read-only)
"w" (read/write enabled)
(4) An user-created file has the read/write attribute, if it has not been changed.
Displays/changes the file attribute of the file stored in the CPU
module.
When displaying the file attribute:
quote change FILE PATH
Either of the following is displayed as the execution result
after a successful completion:
• When the designated file is a read-only file
: "-----R"
• When the designated file is a file with read/write enabled
: "-----W"
When changing the file attribute
quote change FILE PATH ATTRIBUTE
Designate either of the following for the attribute:
• To change to read-only file
• To change to read/write enabled : w
To display the file attribute for the file stored in the RAM area
of memory card:
quote change 1:\MAINSEQ1.QPG
To change the file attribute of the file stored in the RAM area
of memory card:
quote change 1:\MAINSEQ1.QPG r
• When the programmable controller CPU is set to RUN, an
error occurs when the following files are designated:
Parameter file
File currently being executed by the program memory
(drive name:0)
• The attribute changing is possible between read-only file
and read/write enabled file.
• See sections 5.5 and 5.6.1.
MELSEC-Q/L
: r
5 - 29

Advertisement

Table of Contents
loading