Every tripped alarm needs to be RESET. SMΩRF provides three (3) methods how to reset tripped alarm, AUTO,
PTT and MANUAL.
AUTO resets alarm automatically when defined AUTO time expires. It doesn't require output power to
cease, but if alarm condition is matched when alarm is auto-cleared alarm re-triggers.
AUTO reset time can be set to 1 – 99 seconds. This reset is suitable for occasional alarms and low
importance WARNING level when there is no risk of damage caused by consecutive, alarm tripping.
PTT resets alarm when PTT is released and RF power disappears.
MANUAL reset requires intentional operator response, alarm must be cleared by buttons on SMΩRF's
front panel. ← SCREEN button or knob button snoozes alarm, → SCREEN button resets alarm. Alarm
can be reset also remotely from the remote control application running on the computer. It is
recommended to use MANUAL reset for FAULT level of alarms which makes you aware of critical
situation, especially when combined with TX BREAK action. When MANUAL reset is selected, alarm
pop-up window appears even if its appearance is disabled.
Special reset choice for tripped alarm is snoozing. Tripped alarm can be SNOOZED for defined period of time in
minutes in the SNZE field [3]. If alarm is snoozed and during snooze period the tripping condition is matched,
alarm is ignored. This applies only to same alarm type and same importance level as was snoozed.
1
1
2
3
CONTROLS:
ENABLE
1.
Globally enables or disables alarm type for all screens of the sensor.
2.
AUTO
Sets time in seconds [s] for AUTO reset.
SNZE
3.
Sets time in minutes [m] for alarm snoozing.
ACTION
4.
Sets action when alarm is tripped.
RESET
5.
Sets reset method for tripped alarm.