METER MODE is important system setting which defines how SMΩRF has to handle sensors and sets
relationship to radios and iLINK bus. Setting correct meter mode is essential for proper SMΩRF functionality,
especially if you are using more than one sensor, more than one SMΩRF device and connecting them to iLINK
bus.
First (default) meter mode is SINGLE RADIO / SINGLE SENSOR mode. Choose this METER MODE if you are
using only one sensor connected to the SMΩRF. Power Amplifier (PA) drawn on screen is optional.
Keep following setup instructions:
Sensor must be connected to SENSOR 1 IN ports, IN1/IN2.
If you are connecting two SMΩRF boxes to iLINK bus of MK2R+, it is necessary to set radio assignment,
it defines which SMΩRF belongs to the RADIO 1 and which belongs to the RADIO 2.
1
2

METER MODE

1.
Sets meter mode of the SMΩRF.
2.
RADIO ID ASSIGNMENT
Sets radio assignment for iLINK bus.
Available choices are RADIO 1 (ID=1) and RADIO 2 (ID=2).
Controls apply to all meter modes.
Choose this METER MODE if you are using two sensors and both sensors are connected to the different RF
ports of the same transceiver. Typical application is a HF + VHF/UHF transceiver. Both Power Amplifiers
(PA1/PA2) drawn on the screen are optional.
Keep following instructions:
Sensor 1 must be connected to SENSOR 1 IN ports, IN1/IN2.
Sensor 2 must be connected to SENSOR 2 IN ports, IN3/IN4.
If you are connecting two SMΩRF boxes to iLINK bus of MK2R+, it is necessary to set radio assignment,
it defines which SMΩRF belongs to the RADIO 1 (ID=1) and which belongs to the RADIO 2 (ID=2).