Alarms settings and adjustments will be described in details in separate chapters, but now it is necessary to put
in some introduction.
SMΩRF has built-in five (5) type of user configurable alarms in three (3), "importance" levels. Each alarm
"importance" level (Warning, Alarm, Fault) can be individually configured for related action (visibility, audibility
and TX break) for two power levels on per sensor, per band basis.
There are three (3) commonly used alarms – SWR Alarm, High Power Alarm, and Low Power Alarm and two
advanced alarms – PSK IMD alarm and ARCING alarm.
While Alarms settings are individual for each sensor, their settings apply to all sensor's SCREENs.
SCREEN MENU allows further setting, individually enable or disable each level of main three alarms (SWR, Hi-
Power, Lo-Power) on per screen basis. For example, in this way you can disable Warning and Alarm level
keeping just Faults of SWR or Low Power alarms in specific measurement screens (oscilloscope) or entirely
disable Low Power alarm for PSK screen, etc etc ... as you wish to best fit to your needs.
To enable (YES) or disable (NO) particular importance level of the alarm, select required cell in the table and turn
the knob.