Large Screen - microHAM SMORF Manual

Rf vector signal meter
Table of Contents

Advertisement

REFLECTED POWER
2.
REF
TX
Reflected power at the TX (Sensor) feed point.
REF
ANT
Reflected power at the ANT (Antenna) feed point.
REFLECTION
3.
SWR
TX
Standing Wave Ratio at the TX (Sensor) feed point.
SWR
ANT
Standing Wave Ratio at the ANT (Antenna) feed point.
RL
TX
Return Loss [dB] at the TX (Sensor) feed point.
RL
ANT
Return Loss [dB] at the ANT (Antenna) feed point.
4.
IMPEDANCE
IMP
TX
Rectangular coordinates R + jX complex impedance at the TX (Sensor) feed point.
IMP
TX
Polar coordinates |Z|Φ complex impedance at the TX (Sensor) feed point.
IMP
ANT
Rectangular coordinates R + jX complex impedance at the ANT (Antenna) feed point.
IMP
ANT
Polar coordinates |Z|Φ complex impedance at the ANT (Antenna) feed point.
1
2
Large screen is a screen providing two (2) user configurable measurements when there is no need to monitor
many parameters at once, rather have non-disturbing, transparent, fast and as large as possible readout of basic
parameters. Good for contesting or as general screen for users preferring large digits.
Available measurements:
1.
FORWARD
FWD
TX -REF
Peak envelope forward power minus reflected power (delivered power) at the TX feed point.
FWD
ANT -REF
Peak envelope forward power minus reflected power (delivered power) at the ANT feed point.
FWD
TX
Forward power at the TX (Sensor) feed point.
FWD
ANT
Forward power at the ANT (Antenna) feed point.