TL PARAMETERS
4.
R, X
•
Rectangular coordinates complex impedance for both TX and ANT points.
Z = R + jX; R = Resistance [Ω], X = Reactance [Ω]
|Z|Φ
•
Polar coordinates complex impedance for both TX and ANT points.
Z = |Z|e
jΦ
; |Z| = Impedance magnitude [Ω], Φ = Phase [º]
G, B
•
Rectangular coordinates complex admittance for both TX and ANT points.
Y = G + jB; G = Conductance [S], B = Susceptance [S]
Y, Φ
•
Polar coordinates complex admittance for both TX and ANT points.
Y = |Y|e
jΦ
; |Z| = Admittance magnitude [S], Φ = Phase [º]
Γ, Γ
•
Rectangular coordinates complex reflection coefficient for both TX and ANT points.
Γ = Re {Γ} + j Im {Γ}; Real and Imaginary part of the reflection coefficient Γ
Γ, Φ
•
Polar coordinates complex reflection coefficient for both TX and ANT points.
Γ = |Γ|e
jΦ
; |Γ| = Reflection coefficient magnitude, Φ = Phase [º]
REACTANCE EQUIVALENT CIRCUIT
5.
Switches between series (s) and parallel (p) reactance equivalent circuit.
•
TRANSMISSION LINE LOSS
6.
Shows total loss in transmission line from the TX feed point to the ANT feed point. Value can be
•
presented in Watts [W], dBm or dBW units.
Screen has no special settings in SCREEN MENU and by default is not shown between SCREENs rotation.
Visibility can be turned on in SYSTEM MENU | SCREENS MANAGEMENT | SENSOR x SCREENS ORDER.