05.07
Standard upload
The hierarchy level in which the NC data is uploaded to DNC is specified here.
0 =
Standard upload to the machine directory.
1 =
Standard upload to the group directory (father) that is at a higher level than
the machine directory.
2 =
Standard upload to the group directory (grandfather) that is at a higher level
than the group directory of the machine directory.
Extract from the configuration file:
Section[MACHINE]
DefUpload = 0
Start of the view
This parameter specifies the standard directory at the start of DNC IFC.
0=Machine
1=Group
2=Higher-level group
Extract from the configuration file:
Section[GLOBAL]
StartupLayer =0
DNC host path name
The drive specification for DNC host path names must be specified from the
DNC IFC SINUMERIK viewpoint.
It is the specification of the directory in which the NC data can be found on the
networked DNC computer.
Note
The path specification for Windows computers or UNIX/LINUX computers with
Samba:\\DNC
Option for swapping out the NC data on a UNIX system:
The path specification is, for example, for UNIX/LINUX computers with FTP:
/DNC computer name/DNC data directory.
Extract from the configuration file:
Section[PATHS]
WorkPathDNC=\\MCISDNC2\DNC$\Data
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC IFC SINUMERIK - Downloading NC Data via a Network (FBDN2)
computer name\DNC data directory.
5 Configuration file