Siemens Sinumerik 840D sl Function Manual page 206

Motion control information system
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

DNC Plant/DNC Cell (FBDN1)
10 Configuration
NCU ID
Designation (ID) of the controller for M:N functionality.
Extract from machine configuration file:
NCU_Id=1
Protection level
To access the SINUMERIK* machines operated with a high protection level
(0-3) from DNC, you have to set the appropriate protection level for downloads
and uploads in DNC. For this purpose, you have to enter the protection level in
the MCF file. If this is configured, prior to the download/upload, the protection
level on the machine is fetched, possibly the appropriate password set, and
after the download/upload reset again.
Changing the protection level by DNC also acts on the SINUMERIK user
interface, i.e. the machine operator has all operating capabilities possible with
this protection level!
Protection level 0:
Protection level 1:
Protection level 2:
Protection level 3:
Extract from machine configuration file:
NC_ACCESLEVEL=3=
DHS wait time
Time interval during which calls made to the data management server are
monitored (The default value should be used.)
Extract from the machine configuration file:
DCOMDhsWait=20
Internal PCU path
This parameter controls the evaluation and generation of a header with an
internal path (Siemens program header) in the NC data file.
Checkbox not activated: No evaluation
Checkbox activated: One or more paths evaluated
Extract from machine configuration file:
Section[PATHS]
!
Warning
The check to determine whether an NC data file already exists on the controller can
only be carried out correctly if this checkbox has not been selected.
FBDN1/10-198
System password
Manufacturer password
Service password
User password
DriveInternPath
=2
Motion Control Information System DNC (FBDN) - 04/10 Edition
© Siemens AG 2010 All Rights Reserved
05.07