Standard machine configuration file for serial connection without protocol

Table 10-11: Example of a standard machine configuration file for serial connection without protocol

; MCIS DNC V2 Machine configuration templatefile
; Base: "__standard-serial.MCF"
; more infos see the machine configuration documentation on
; Install-CDROM in "IBS_Docu\Machine-configuration-docu\*.pdf"
;
[GLOBAL]
MachineType=serial
MachineServer=SerIntSvr.Machine
;
[SERINTSVR]
;CNCConverter=DNCConv.CodeConvert
CNCConverter=
;Server for Code conversion
[DNCConv]
;CNCcode=
(ASCII,ISO,EIA)
CNCcode=ISO
;Serial COM-port Paramter
[COM]
;---CommPort---:
ComPort =
2
;---BaudRate---: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 ;57600, 115200
Bd
BaudRate = 9600
;---ByteSize---: 6,7,8
ByteSize = 8
;---StopBits---: 1, 2
StopBits = 1
;---Parity---: No=N, Odd=O, Even=E; Mark=M; Space=S
Parity = N
;---FlowCtrl---: DTRDSR, RTSCTS, XONXOFF, NONE
FlowCtrl = RTSCTS
;---XON/XOFF---: in ASCII-decimal- Code (0 ... 255)
XONChar=17
XOFFChar=19
;---Binary---: 0= NO 1 = YES (transfermode: 0=ASCII, 1=binary)
Binary = 0
;Program Output Parameter
[SEND]
;Parameters in ASCII- Dezimal- Code (0 ... 255)
;---ProgramStart---: (character, added before each file)
ProgramStart=0
;---ProgramEnd---: (character, added after each file)
ProgramEnd=0
;---CommentStart---: (character which marks the begin of an comment)
CommentStart=40
;---CommentEnd---: (character which marks the end of an comment)
CommentEnd=41
;---HeaderChar---: (character, added "HeaderSize"-times before each file)
HeaderChar=0
;---TrailerChar---: (character, added "TrailerSize"-times before each file)
TrailerChar=0
;---HeaderSize---: (Size in Bytes to add Parameter "HeaderChar" before each file)
HeaderSize=0
;---TrailerSize---: (Size in Bytes to add Parameter "TrailerChar" after each file)
TrailerSize=0
;---SpacerChar---: (character, added "SpacerSize"-times before/after each SpacerMark)
SpacerChar=0
;---SpacerSize---: (Size in Bytes to add Parameter "SpacerChar" before/after each
SpacerMark)
SpacerSize=0
;---SkipFirstSpacerMark---: 0= NO 1 = YES (to suppress Spacer before 1. NC Programm)
SkipFirstSpacerMark=0
;---SpacerMarkers (max 16 Byte each)
;---SpacerMark1..3 ---: (before each line in which these SpaceMarkers appear a spacer
will be inserted)
;SpacerMark3=%MPF
SpacerMark1=
SpacerMark2=
SpacerMark3=