Configuration For The File System Connection Type - Siemens Sinumerik 840D sl Function Manual

Motion control information system
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

05.07

10.5.4 Configuration for the file system connection type

The file system machine type can be used to transfer NC data from and to any
network drives that have been released. Any network-capable controller can be
connected to the DNC system under Windows. Two directories have to be
configured for downloading and uploading NC data.
A conversion of the file type can be configured for the download or upload. This
configuration can appear only in the machine configuration file.
See also: Standard machine configuration file for the file system connection type
Configuration dialog for the file system connection type
Fig. 10-20: File system config dialog
Note
Only users with the appropriate configuration authorization are permitted to define
directories for the file system machine type.
Send directory
The send directory is the directory to which the NC data is to be downloaded.
Receive directory
When the NC data is uploaded, it is transferred to the specified receive directory in
accordance with the version strategy.
Note
The directories are not specific to a particular computer when they are specified
in UNC notation (e.g. \\Server1\DNC\Data).
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC Plant/DNC Cell (FBDN1)
10 Configuration