05.07

5.2.2 DNC

Fig. 5-3: Configuration user interface / DNC
The connection to the higher-level DNC system and the identification of the PCU in
the DNC system are defined in the DNC tab.
DNC database
The option button is used to select the database that will be used in the DNC
system:
MSDE / SQL Server (DNC_IFC.INI: 0)
Oracle (DNC_IFC.INI: 1)
Extract from the configuration file:
Section [GLOBAL]
DataBaseType =0
DNC host name or TCP/IP address
The TCP/IP address or the computer name of the DNC host (DNC CELL or DNC
PLANT) is entered in the entry field. A connection test can be performed by
clicking the Test connection button.
Extract from the configuration file:
Section [GLOBAL]
DNC-HOST =192.168.1.100
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC IFC SINUMERIK - Downloading NC Data via a Network (FBDN2)