Siemens Sinumerik 840D sl Diagnostic Manual page 65

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
6413
[Channel %1: ] Tool %2 has reached its monitoring limit with D = %4
Parameters:
%1 = TO unit
%2 = Tool identifier (name)
%3 = -Not used-
%4 = D number
Definitions:
Tool monitoring: This message informs that the specified D offset has reached its prewarning limit for
a time-, quantity- or wear-monitored tool. If possible, the D number is displayed; if not, value 0 is
assigned to the 4th parameter.
If the function additive offset is being used, additive offset monitoring may be active instead of tool
wear monitoring.
The actual type of tool monitoring is a tool property (see $TC_TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm originates during NC program execution.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6415
[TO unit %1: ] Tool %2 with tool edge no. %3 has reached tool monitor
warning limit
Parameters:
%1 = TO unit
%2 = Tool identifier
%3 = Cutting edge number
Definitions:
This message informs that at least one cutting edge of the time or quantity monitored tool has reached
its monitoring limit. The alarm was triggered through the OPI interface (MMC, PLC). The channel con-
text is not defined. The TO unit was specified for this reason.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6416
[Channel %1: ] Tool %2 with tool edge no. %3 has reached tool monitor
warning limit
Parameters:
%1 = Channel number
%2 = Tool identifier
%3 = Cutting edge number
Definitions:
This message informs that at least one cutting edge of the time or quantity monitored tool has reached
its monitoring limit. The limit was detected in the channel context. The alarm originated during NC pro-
gram execution.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-65