Siemens Sinumerik 840D sl Diagnostic Manual page 257

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
16688
[Channel %1: ] Block %2 following axis/spindle %3 coupling type %4
maximum number of master values exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Coupling type
Definitions:
The maximum number of master values has been exceeded for the stated type of generic coupling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program, reduce number of master values or use a different type of coupling.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16689
[Channel %1: ] Block %2 following axis/spindle %3 coupling type %4
maximum number of master values exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Coupling type
Definitions:
The maximum number of master values has been exceeded for the stated type of generic coupling.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program, reduce number of master values or use a different type of coupling.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16690
[Channel %1: ] Block %2 following axis/spindle %3 changing the
reference system %4 is not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions:
An attempt was made to change the reference system with generic coupling active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part programm.
End coupling and reactivate with desired reference system.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16691
[Channel %1: ] Block %2 following axis/spindle %3 changing the
reference system %4 is not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions:
An attempt was made to change the reference system with generic coupling active.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part programm.
End coupling and reactivate with desired reference system.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-257

Hide quick links: