Off Premise Extension (Opx) (Figure 5-3) - Samsung DCS-816 Programming Manual

Table of Contents

Advertisement

SAMSUNG
DCS-816

5.3 Off Premise Extension (OPX) (Figure 5-3)

The Basic KSU is equipped with four (4) SLI interfaces and only the first two (2) SLI interfaces are
specially designed for Long Line or Off Premise Extension (OPX) connections. The interfaces
have the same over-voltage and over-current protection circuits as an analogue trunk interface.
All connections for OPX lines can be done through the RJ-45 connector on the base board. See
Figure 2-3 and refer to the section 2.5 (MDF Cabling).
Use one pair twisted wires and connect each OPX line to the SLI port of your choice via the RJ-45
connector on the base board.
4 PAIR CABLE WITH MALE CONNECTOR TO THE BASE RJ-45 CONNECTOR
Long Line
Extension
CONNECTING OPX LINES
RJ-45 CONNECTION
PIN COLOUR
1/ 8 W-BL/ BL-W
2/ 7 W-O/ O-W
² NO POLARITY
² A LOOP-DISCONNECT FACILITY PER LINE
² CONNECT TO ONE OF THE 1
CIRCUITS ON THE BASE BOARD VIA THE RJ-45
CONNECTOR.
CIRCUITS/ FUNCTIONS
T/R, 1
T/R, 2
ST
OR THE 2
5-4
Installation
February, 1999
st
SLI on base board
nd
SLI on base board
ND
SLI
FIGURE 5-3

Hide quick links: