5.3 Off Premise Extension (OPX) (Figure 5-2)

The basic KSU is equipped with four (4) SLI interfaces. Only the first two (2) SLI interfaces are
specially designed for Long Line or Off Premise Extension (OPX) connections. The interfaces
have the same over-voltage and over-current protection circuits as an analogue trunk interface. All
connections for OPX lines can be done through the RJ-45 connector on the base board. See Fig-
ure 2-3 and refer to the section 2.5 (MDF Cabling).
Use one pair twisted wires and connect each OPX line to the SLI port of your choice via the RJ-45
connector on the base board.
4 PAIR CABLE WITH MALE CONNECTOR TO THE BASE RJ-45 CONNECTOR
Long Line
Extension

CONNECTING OPX LINES

RJ-45 CONNECTION
PIN COLOUR
1/ 8 W-BL/ BL-W
2/ 7 W-O/ O-W
NO POLARITY
A LOOP-DISCONNECT FACILITY PER LINE
CONNECT TO ONE OF THE 1
CIRCUITS ON THE BASE BOARD VIA THE RJ-45
CONNECTOR.
5-3
RJ-45 CONNECTION
PIN COLOUR
Installation Manual
CIRCUITS / FUNCTIONS
st
T/R, 1
SLI on base board
nd
T/R, 2
SLI on base board
ST
ND
OR THE 2
SLI
FIGURE 5-2