Samsung DCS-816 Programming Manual page 125

Table of Contents

Advertisement

SAMSUNG
DCS-816
MMC: 501
DESCRIPTION:
Allows the technician to adjust individual timers as necessary. Any timer can be
disabled by setting the time to all zeros (000).
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
ACTION
1. Press TRSF 501
Display shows first timer value
2. Press UP or DOWN key to select timer and press
RIGHT soft key to move cursor
3. Enter new value using keypad; if valid, system
returns to step 2 with new value
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: See table of timers and values, below
RELATED ITEMS: None
SYSTEM–WIDE TIMERS
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
MMC 501 (Page 1 of 7)
Programming
February, 1999
DISPLAY
AA INT DGT TIME
05 SEC →
KMMC LOCK OUT TM
30 SEC → _
KMMC LOCK OUT TM
30 SEC → 255

Hide quick links: