HUAWEI MU609 HSPA LGA Module
Application Guide

9.2.2 Troubleshooting

Scenario
AT+CRSM=178,12258,0,0,
10
AT+CRSM=220,28476,1,4,
176,"1111","7F10"
Issue 02 (2013-09-18)
Possible Error
Information
+CRSM: 105,129,""
OK
+CRSM: 105,130,""
OK
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
SIM Operation Application Scenarios
Solution
The status word (SW)
indicates a Read command
error occurred. Files with a
structure should be
transparent
read using 176 (READ
BINARY).
The PSW indicates that the
security conditions were not
met. To update the EFsms
file, the correct PIN is
required.