5.4.1 Reference Process

Command
AT^IPINIT="1234","card","card"
OK
AT^IPOPEN=1,"TCP","172.22.44.33",5000,5500 Create a link.
OK
AT^IPSEND=1,"31323334"
^IPSEND: 1
OK
^IPDATA: 1,8,31323334
AT^IPSENDEX=1,0,"31323334"
^IPSENDEX: 1
OK
^IPDATA: 1,8,31323334
AT^IPSENDEX=1,1,"31323334"
^IPSENDEX: 1
OK
^IPDATA: 1,4,1234
AT^IPSENDEX=1,2,<datalen>
OK
(Wait for the user to enter user data with a
length of <datalen>)
^IPSENDEX: 1
OK
Issue 02 (2013-09-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Internal Protocol Stack Application Scenarios
Description
Initialize the internal protocol
stack.
Send data. In this example,
31323334 is sent.
Data is successfully sent and
received.
Send data in mode 0. In this
example, 31323334 is sent.
Send data in mode 1. In this
example, 1234 is actually
sent.
Send data in mode 2.
37