Periodically Querying The Version; Reference Process - Huawei MU609 Application Manual

Hspa lga module
Hide thumbs Also See for MU609:
Table of Contents

Advertisement

HUAWEI MU609 HSPA LGA Module
Application Guide
Scenario
The module reports a
query failure.

16.5 Periodically Querying the Version

16.5.1 Reference Process

Command
AT^FOTAMODE=1,0,0,1,7
OK
^FOTASTATE: 11
^FOTASTATE:
12,12.815.01.04.00,79114,"Support
send sms background"
Notes:
Issue 02 (2013-09-18)
Periodical query is based on either of the two timekeeping modes: network timekeeping or
local timekeeping. If network timekeeping is unavailable, local timekeeping is used. Local
timekeeping may not be accurate.
Local timekeeping is affected by AT+CCLK command. Upon a power-off event, the CCLK
value changes to 1980. After you choose to use local timekeeping and change the CCLK
value, the query operation cannot be carried out at the correct time.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Possible Error
Information
^FOTASTATE:
13,<error_code>
Description
Configure FOTA mode as auto query, auto
download, auto upgrade, and resumable
data transfer enabled and the query cycle
to seven days.
The command is successfully executed.
The module automatically checks for
updates when the query time arrives.
Report that the query operation is in
process.
Report information about the new version.
FOTA Application Scenarios
Solution
Upon a query failure, the
module restores the FOTA
state to idle and deletes the
downloaded files. For error
codes, see the latest
version of MU609
V100R002 in
HUAWEI
MU609 HSPA LGA Module
AT Command Interface
Specification.