8.3.2 Troubleshooting

Scenario
Error information is
returned in response
to one of the previous
commands.
AT^CPBR=<index1>
AT^CPBR=<index1>,
<index2>
AT^CPBR=<index1>
AT^CPBR=<index1>,
<index2>
Issue 02 (2013-09-18)
Possible Error
Information
+CME ERROR: SIM
busy
+CME ERROR: SIM PIN
required
+CME ERROR: SIM
PUK required
+CME ERROR: invalid
index
+CME ERROR: invalid
index
+CME ERROR: not
found
+CME ERROR: not
found
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Phonebook Application Scenarios
phone number, and the maximum
length (<tlength>) of a name.
Solution
Phonebook initialization has
not completed. Try again later.
Enter the correct PIN.
Enter the correct PUK.
The index is invalid. Check
that index 1 is within the
supported range.
The index is invalid. Check
that index 1 and index 2 are
within the supported range and
that index 1 is not greater than
index 2.
No entries are found in the
storage locations in index 1.
Check that there have been
entries successfully written into
these locations.
No entries are found in the
storage locations between
index 1 and index 2. Check
that there have been entries
successfully written into these
locations.
69