Application Guide
The AT command "AT+IPR?" will return the baud rate, but the baud is not what the
host set or have no response by the UART.
The AT command "AT+CGDCONT?" will return the pdp profile, but the pdp profile will
be empty or not the same as that the host set.
Host Resume Steps
In this condition, the host need reconfigure the setting. We suggest the host configure
the setting after powering on the module.
Host Resume Example
Try to connect the module with the baud rates the module supports, and change the
baud rate that the host needs.
Run:
Response:
Issue 02 (2013-09-18)
AT+IPR=115200
OK