ABB PSTX30 Installation And Commissioning Manual page 123

Hide thumbs Also See for PSTX30:
Table of Contents

Advertisement

Parameter
Description
number
28
Service
28.01
ID
28.02
Line contactor close time
28.03
TOR relay delay time
28.04
Start without start command
28.05
Step down level
28.06
Torque profile start
28.07
Torque finish
28.08
Torque tune
28.09
Torque ctrl gain
28.10
Torque PI intergration time
28.11
Torque slip
28.12
Torque diff
28.13
Torque filter time
28.14
Mains lock setting
28.15
Minimum trig time
28.16
Accel adapt U start ramp
28.17
U start ramp switch level
28.18
T start ramp switch level
28.19
Stop ramp switch level
28.20
In-Line gain
28.21
Inside delta gain
28.22
Phase loss
28.23
Phase loss during TOR
28.24
Phase loss trip time
28.25
Phase loss trip angle 1
28.26
Phase loss trip angle 2
28.27
Bad network quality
28.28
Low supply voltage
28.29
High current fault
28.30
Shunt fault
28.31
Short circuit thyristor
28.32
Open circuit thyristor
28.33
Thyristor overload
28.34
Heat sink over temp
28.35
Faulty connection
28.36
Faulty usage
28.37
Close bypass curr lvl
28.38
Simulation motor
28.39
Simulation load
28.40
Simulation connection
28.41
System mode
28.42
Limp mode
28.43
Motor connection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Setting range
Invalid ID, 30, 37, 45, 60, 72, 85, 105, 142, 170,
210, 250, 300, 370, 470, 570, 720, 840, 1050,
1250
0 ... 65535 ms
0 ... 300 s
On / Off
10 ... 100 %
Constant setpoint, Linear ramp,
Progressive curve, High inertia curve
30 ... 500 %
0 ... 1000 %
0.01 ... 10.00
0.001 ... 10 s
0.1 ... 100 %
0.1 ... 100 %
0.01 ... 100 s
Automatic lock, 50 Hz manual lock
60 Hz manual lock
0.0 ... 1.0 ms
On / Off
10 ... 100 %
10 ... 100 %
10 ... 100 %
0.0 ... 30.0
0.0 ... 30.0
On / Off
On / Off
20 ... 4000 ms
1 ... 240
1 ... 240
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
0.5 ... 4.0 x I e
M3AA 100L 2 (Ie = 5.2 A), M3BP 112M 4
(Ie = 7.4 A), M2AA 180MLA 6G (Ie = 29.3 A),
M2AA 180MLB 4G (Ie = 39.9 A), M3AA 250SMA 8
(Ie = 62.3 A), M3AA 200MLB 2 (Ie = 59.2 A),
M2AA 225SMA 2G (Ie = 74.7 A), M2BP 250SMA
4G (Ie 96.6 A), M2BA 280SMB 2L (Ie = 144.9 A),
M2BA 315SMB 4L (Ie = 221.8 A), M2BA 315MLA
2L (Ie = 319.6A), M4BP 200MLB 2G (Ie = 59.3 A),
M3BP 315LKB 4K (Ie = 330.4 A), M3BP 315MLA
2M (Ie = 255.4 A),M3BP 280MLA 4M (Ie 151.5 A),
M3BP 355SMC 6K (Ie = 325.6 A),
No load, Linear Load, Progressive load,
High inertia load
Auto, In line, Inside delta UI, Inside delta IU, Two
phase (L1 shorted), Two phase (L2 shorted), Two
phase (L2 shorted), Unknown
Normal, Demo, Small motor
On / Off
Auto, In line, Inside delta UI, Inside delta IU, Two
phase (L1 shorted), Two phase (L2 shorted), Two
phase (L2 shorted), Unknown
Number of
Fieldbus
Default value
decimal
ID
0
171
Invalid ID
0
175
245 ms
1
-
0 s
0
-
Off
0
9
80 %
0
10
Linear ramp
0
17
100 %
0
11
100 %
2
12
0.02
3
13
0.004 s
1
14
1.0 %
1
15
2.0 %
2
16
0.02 s
0
-
Automatic lock
3
-
0.208 ms
0
-
Off
0
-
22 %
0
-
30 %
0
-
52 %
1
-
0.0
1
-
3.0
0
33
On
0
-
On
0
34
500 ms
-
0
12
0
0
70
0
35
On
0
37
On
0
38
On
0
40
On
0
39
On
0
-
On
0
41
On
0
-
On
0
-
On
0
-
On
1
28
1.2 x I e
0
29
M3AA
250SMA 8
(Ie = 62.3 A)
0
30
Progressive
load
0
-
In line
0
31
Normal
0
25
Off
0
27
Auto
Actual
setting
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents