Commissioning
In this way, the Light Controller can approach the setpoint value in fast
steps. The increment should always be considered in conjunction with both
approach parameters. Both parameters change the control dynamics and
the approach speed to the setpoint value.
For further information see:
Control deviation for high increments
Options:
0...1...30
This value defines a range around the setpoint at which no light control
occurs. Only after the actual value (brightness value) is again outside this
range does light control recommence. In this way continuous control with
the respective changes in brightness is avoided. This generates a smoother
and less abrupt response and considerably reduces the bus load with
a master/slave control.
For further information see:
Constant lighting control
Constant lighting control
71