...2 OPERATION
...2.6 Process View
Configuration
Setup
View Select
Alarms
Statistics
Operator Messages
1 - 6
Start of batch
7 - 12
End of batch
13 - 18
Standby mode active
19 - 24
Cleaning in progress
<user defined>
No message
No message
Totalizer Stop/Go
Ch 1.1 Level
Ch 1.2 Pressure
Ch 1.3 In Flow
Ch 1.4 Out Flow
Stop
Ch 1.5 Temp
Go
Ch 1.6 Alarm 1
All
Totalizer Reset
Ch 1.1 Level
Ch 1.2 Pressure
Ch 1.3 In Flow
Ch 1.4 Out Flow
Ch 1.5 Temp
Ch 1.6 Alarm 1
Alarm Acknowledge
Ch 1.1 Level
Ch 1.2 Pressure
Ch 1.3 In Flow
Ch 1.4 Out Flow
Ch 1.5 Temp
Ch 1.6 Alarm 1
All
AutoView Scroll
16
Select the Configuration level – see Section 4.
Select the Set Up level – see Section 3.
Switch between the Alarm View and Statistics View.
Note. If a channel's totalizer has not been enabled in the Configuration level, Alarm trip
levels are shown in place of the channels statistics. If no alarms are enabled, the channel
long tag is displayed for that channel.
Add one of 24 predefined Operator Messages (see Section 4.4.5) or one User Defined
Message to the alarm event log. If User Defined is selected, a data entry keyboard appears
to enable the message to be entered – see Fig. 4.5. The selected or user defined message
is displayed on-screen briefly.
Stop and start individual totalizers.
Notes.
• Channel totalizers that have not been enabled in the configuration level are shown
greyed out.
• When a totalizer is not running (i.e. Stop is selected), the corresponding totalizer value is
shown in red.
Reset the totalizer value to the totalizer preset value.
Note. Channel totalizers that have not been enabled in the Configuration level are shown
greyed out.
Acknowledge active alarms in the current process group, either individually or globally.
Note. Active alarms are identified by a flashing red 'Alarm Status' icon in the bottom left
hand corner of the associated channel indicator and a Global Alarm icon in the title bar –
see Fig. 2.6. If the Global Alarm icon is surrounded by a flashing red border, an active alarm
is unacknowledged.
If neither alarm on a particular channel is configured, the channel short tag is greyed out in
the menu.
Select AutoView Scroll to display the chart for each configured process group in turn for 40
seconds. The AutoView Scroll icon (
screen when AutoView Scroll is active. Press any key to cancel AutoView Scroll.
) is displayed in the status bar at the top of the