345 FORMAT CODES
Code
0xA5C2
0xA5C4
0xA601
0xA602
0xA604
0xA641
0xA642
0xA644
0xA681
0xA682
0xA684
0xA6C2
0xA702
0xA842
0xA882
0xA8C2
0xA902
0xA942
0xA982
0xA9C2
0xAA02
0xABC1
0xABC2
0xABC4
0xAC01
0xAC02
0xAC04
0xAC42
0xACC2
0xAD01
0xAD02
0xAD04
0xAD41
0xAD42
0xAD44
0xAD81
0xAD82
0xAD84
0xADC2
0xAEC2
0xAF41
0xAF42
0xAF44
0xB001
0xB002
0xB004
0xB041
11-144
Type
Definition
LE 5 Alarm OP
LE 5 Alarm DPO
LE 6 Alarm PKP
LE 6 Alarm OP
LE 6 Alarm DPO
LE 7 Alarm PKP
LE 7 Alarm OP
LE 7 Alarm DPO
LE 8 Alarm PKP
LE 8 Alarm OP
LE 8 Alarm DPO
Curr Dmd1 Alrm OP
Curr Dmd2 Alrm OP
W1BKR Alarm
W1BKR Trip Time
W1BKR Close Time
W1BKR Charge Time
W2BKR Alarm
W2BKR Trip Time
W2BKR Close Time
W2BKR Charge Time
HI Amb Temp PKP
HI Amb Temp OP
HI Amb Temp DPO
LO Amb Temp PKP
LO Amb Temp OP
LO Amb Temp DPO
Self Test Alarm OP
BKRTrpCntrAlrm OP
R1 CoilMonAlrm PKP
R1 CoilMonAlrm OP
R1 CoilMonAlrm DPO
R2 CoilMonAlrm PKP
R2 CoilMonAlrm OP
R2 CoilMonAlrm DPO
BKR1 Fail Alrm PKP
BKR1 Fail Alrm OP
BKR1 Fail Alrm DPO
BKR Stat Fail OP
BKR2 Stat Fail OP
BKR2 Fail Alrm PKP
BKR2 Fail Alrm OP
BKR2 Fail Alrm DPO
Ph IOC1 Alarm PKP
Ph IOC1 Alarm OP
Ph IOC1 Alarm DPO
Ntrl IOC1 Alrm PKP
CHAPTER 11: 345 MODBUS MEMORY MAP AND FORMAT CODES
Long Description
Logic Element 5 Alarm OP
Logic Element 5 Alarm DPO
Logic Element 6 Alarm PKP
Logic Element 6 Alarm OP
Logic Element 6 Alarm DPO
Logic Element 7 Alarm PKP
Logic Element 7 Alarm OP
Logic Element 7 Alarm DPO
Logic Element 8 Alarm PKP
Logic Element 8 Alarm OP
Logic Element 8 Alarm DPO
Current Demand 1 Alarm OP
Current Demand 2 Alarm OP
W1 Breaker Alarm
W1 Breaker Trip Time
W1 Breaker Close Time
W1 Breaker Charge Time
W2 Breaker Alarm
W2 Breaker Trip Time
W2 Breaker Close Time
W2 Breaker Charge Time
High Ambient Temperature Alarm PKP
High Ambient Temperature Alarm
High Ambient Temperature Alarm DPO
Low Ambient Temperature Alarm PKP
Low Ambient Temperature Alarm
Low Ambient Temperature Alarm DPO
Self Test Alarm OP
Breaker Trip Control Alarm OP
Trip Coil Monitor Alarm PKP
Trip Coil Monitor Alarm OP
Trip Coil Monitor Alarm DPO
Close Coil Monitor Alarm PKP
Close Coil Monitor Alarm OP
Close Coil Monitor Alarm DPO
Breaker 1 Fail Alarm PKP
Breaker 1 Fail Alarm OP
Breaker 1 Fail Alarm DPO
Breaker Status Fail OP
Breaker 2 Status Fail OP
Breaker 2 Fail Alarm PKP
Breaker 2 Fail Alarm OP
Breaker 2 Fail Alarm DPO
Phase IOC 1 Alarm PKP
Phase IOC 1 Alarm OP
Phase IOC 1 Alarm DPO
Neutral IOC 1 Alarm PKP
SR3 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE