(3)
Remove 4 screws (2 of them on the front
side are the stepped screws) and take off the
fuser unit lower cover.
(4)
Take off 2 thermostats by removing 2 screws
each.
Note:
The gap between the fuser roller and ther-
mostat is adjusted to be 2.3±0.2 mm with the
screw in the figure at right. Therefore, make
sure not to loosen 4 screws shown in the fig-
ure at right.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
FUSER UNIT
© 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
13 - 18
Stepped screw
Fuser unit lower cover
Fig. 13-26
Thermostat
Fig. 13-27