When the power is turned ON or the LCF drawer is inserted (when the power is turned ON or
equipment drawer / PFP drawers are inserted), LCF (PFP/equipment) performs initialization.
Detects the presence of paper
Tray-up motor ON – The tray goes up
At this time, the tray-up sensor and empty sensor are OFF.
When the tray-up sensor is not turned ON in a fixed period of time, it means that
the tray is in abnormal condition.
"Add paper" is displayed regardless of presence/absence of paper.
Tray-up sensor is turned ON in a fixed period of time.
-
When the paper in the drawer runs out during copying,
The tray-up sensor turned OFF
The tray-up motor turned ON
The tray-up sensor turned ON
Empty sensor turned OFF during the copying in spite of the tray-up sensor is ON
e-STUDIO200L/202L/203L/230/232/233/280/282/283
GENERAL OPERATION
Cleared by turning the power ON/OFF
The tray motor stops.
At this time, if the empty sensor is ON:
Drawer area of the LCD panel blinks (When the drawer is selected)
It is judged that there is no paper.
Drawer area of the LCD panel blinks (When the drawer is selected)
The copying operation is stopped.
It is judged that there is paper.
OFF: It is judged that there is no paper.
Tray goes up
Tray-up motor stopped.