Honeywell ADEMCO VISTA SERIES VISTA-21iP Installation And Setup Manual page 62

Hide thumbs Also See for ADEMCO VISTA SERIES VISTA-21iP:
Table of Contents

Advertisement

Installation and Setup Guide
Internal Device (Ip and GSM) Default Values
The programming default values for ∗29 Menu Mode are listed in the Table below.
OPTION
1
Internal Device
2
Multi-Mode
3
Multi-Mode Address
4
Primary City ID
5
Primary CS ID
6
Primary Sub ID
7
Remote Access
8
Keypad Address (for remote access)
9
Supervision
10
GSM Rollover Y/N
11
GSM 24Hr Tst Y/N
12
Old Alarm Time
13
IP Fault Time
14
GSM Fault Time
15
Notify Panel Of
16
Use DHCP Y/N
17
NIC IP Address
18
Subnet Mask
19
Gateway IP Addr
20
DNS IP Addr.
Status and Contact ID Reporting Codes
The Internal Device (IP/GSM) sends status messages to the control panel for network connectivity failures.
Trouble messages are displayed on the keypad as "Check 103," with status displayed as "LngRng Radio"
followed by a 4-digit keypad display status code, defined below.
Keypad Display Status Codes
CODE
0000
Control panel lost communication with internal device
0005
internal device has lost contact with AlarmNet
000F
internal device is not registered; account not activated
0019
GSM module shut down
0400
internal device Power-on reset AND the control panel lost
communications with IP/GSM
Start ∗29 Menu Mode by pressing *29 while in Data Programming mode.
E N A B L E I P / G S M ?
0 = N o , 1 = Y e s
1 = P R O G 2 = D I A G
0 = Q U I T
Internal Device Programming Prompts
The keys used to select and enter options now follow 7720P keypad emulation. Refer to the table on the
previous page for detailed key functions. The following is a summary:
[∗] = scroll the options of a particular prompt
[#] = accept the entry and move to the next prompt
[A] = backspace or shift-[A} for escape
[B] = scroll to next prompt or shift-[B] scroll to previous prompt
[C] = answer No or shift-[C] answer Yes to prompt
[D] = shift key
5-20
STANDARD DEFAULT VALUE
IP
disabled
?? (if Multi-Mode enabled)
??
??
????
N (disabled)
?? (if Remote Access enabled)
24 Hours
N (if GSM enabled)
N (if GSM enabled)
10 Minutes
00 Minutes
00 Minutes (if GSM enabled)
Neither Fault (if IP and GSM enabled)
Y (if IP or IP/GSM enabled)
255.255.255.255 (if DHCP not used)
255.255.255.255 (if DHCP not used)
255.255.255.255 (if DHCP not used)
255.255.255.255 (if DHCP not used)
DESCRIPTION
Enable INT IP/GSM?
0 = no, not using either IP or GSM; 1 = yes using IP and/or GSM module; [ ∗ ] to continue
NOTE: Default = 1 (IP and/or GSM)
IMPORTANT: If using an external communication device, first follow the instructions in
the Inadequate Signal Strength paragraph in the VISTA-GSM4G Module Installation
section for physical installation of an external communication device. When complete, enter
1 at this prompt and enter 1-Prog at the next prompt. Then program the external device
using the Installation and Setup Guide included with the external communication device.
Fixed-Word Keypad Note: Although programming IP/GSM options cannot be done via a
fixed-word keypad, IP/GSM can be enabled by doing the following:
Enter ∗ ∗ ∗ ∗ 29 (to enter IP/GSM menu mode), then press 1 + [∗ ∗ ∗ ∗ ] + [∗ ∗ ∗ ∗ ]
Programming/Diagnostics Select
1= Prog (program the IP/GSM options)
2 = Diag (enter diagnostic mode) NOTE: If using an external communicator, Diagnostic
mode option available only for communicators with firmware version 2.4.16 or higher.
0 = Quit; return to data field programming mode
ACTUAL ENTRY
Contact ID Codes (as displayed at 685) sent to CS via IP/GSM
CODE
E339 C803
E350 C951
Primary communication path failure (Ethernet) **
R350 R951
Primary communication path restore (Ethernet) **
E350 C952
Secondary communication path failure (GSM) **
R350 C952
Secondary communication path restore (GSM) **
E355 C000
Module lost ECP communication with control
R355 C000
Module restore ECP communication with control
E353 C103
Long range transmitter fault trouble
R353 C103
Long range transmitter fault restore
** reports only if IP and GSM enabled
DESCRIPTION
Power-on reset

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista series vista-21ipsiaAdemco vista-21ipsiaAdemco vista-21ip